Title:Reducer oil inspection and maintenance
Intermixing of different lubricants is prohibited to use. The oil level plug, oil drain plug and the breather is determined by the location of the installation location. Their position can be related to the installation location map reference deceleration machine to determine .

Check the oil level of deceleration
1 , cut off power to prevent electric shock ! Wait cool gear !
2 , remove the oil level plug to check the oil is full .
3 , install the oil drain plug .

Check the oil
1 , cut off power to prevent electric shock ! Wait cool gear !
2 , hit an open oil drain plug , taking oil samples .
3 , check the oil viscosity index
If the oil significantly turbid , it is recommended to be replaced soon .
4, for the band 's gear oil level plug
Check the oil level , eligibility
Install the oil drain plug

Replace the oil
After cooling to increase the viscosity of the oil drain difficulties gear oil change should be at operating temperature.
1 , cut off power to prevent electric shock ! Wait to cool down reducer no danger of burning up !
Note: The gear oil change should remain warm.
2, in the oil drain plug Place a drip tray .
3, open the oil level plug , breather and oil drain plug .
4 , the oil all excluded.
5 , mounted on the oil drain plug .
6 , with the injection of new oil grades .
7, the oil should be consistent with the installation location.
8 , check the oil level at the oil level plug .
9 , tighten the oil drain plug and breather .